ABOUT FIXIN SYSTEM

The FIXIN Implant

FIXIN is an orthopaedic implant for internal fixation with angular stability. It consists of a steel support, with threaded holes where threaded inserts can be secured. The inserts are externally threaded, to be screwed into the support. The inner hole of the insert is conical to lodge the head of the screw. The support together with the inserts form what we traditionally refer to as the plate. The screw is a self-tapping, self-blocking, screw with angular stability. The screw’s head is conical, corresponding perfectly with the conically shaped hole of the insert. A conical coupling occurs between the head of the screw and the insert.

 


- The unique conical screw-plate locking system ensures the distribution of force throughout the structure, eliminating the risk of implant breakage and screws backing out.


- The patented locking system allows easy locking of the screw in the plate and eliminates the possibility of crossthreading the screw head in the plate.


- Easy exchange and removal of screws if needed.


- Simple and intuitive instruments for reduced surgery times.


- Periosteum is left intact to preserve the vascularisation.


- Plate thickeness range from 1,2mm to 2mm in the mini series and from 1,5mm to 3mm in the medium series allows a minimally invasive approach.
 

 


Why the Insert?

Traditional locking plates use a threaded screw-plate locking system. TraumaVet screws have a 2º conical head which locks into a corresponding 2º tapered cone in the bushings, which are pre-assembled on the plate. This coupling eliminates the risk of cross threading between the screw and plate and ensures a simple operative technique. It also permits easy removal of the screws, whether because they have been placed incorrectly intra- operatively, or for later removal of the plate. It is an extremely stable coupling, which effectively transfers loads through the structure and reduces the risk of screws backing out or plate breakage.

 

The FIXIN Instruments

FIXIN instruments set are composed by few items,
are simple to use and easy to prepare for surgery.

 
Series 3,0 – 3,5 mm

COMPATIBLE STANDARD INSTRUMENTS
  • Depth Meter
  • Exagonal Screwdriver Hex Ø 2.5mm


DEDICATED INSTRUMENTS
  • VS35 Bushing Carrier/Extractor
  • VS380 Drill Guide Ø 3.5mm
  • VS381 Drill Guide Ø 3.0mm
  • VS390 Drill Bit Ø 2.9mm
  • VS391 Drill Bit Ø 2.5mm


 
 
Series 1,9 – 2,5 mm

COMPATIBLE STANDARD INSTRUMENTS
  • Depth Meter
  • Hexagonal screwdriver Hex Ø 2


DEDICATED INSTRUMENTS
  • VS210 Drill Guide Ø 2.5mm e Ø 1.9mm
  • VS220 Drill Bit Ø 2.0mm
  • VS221 Drill Bit Ø 1.5mm
  • VS25 Bushing Carrier/Extractor
 
Dedicated drill guide

To allow proper matching between the conical head of the screw and the conical hole of the insert a special drill-guide has been developed The drill guide has a tapered cone and fits directly and securely into the bushes on each plate allowing the surgeon working with both hands.

 


Temporary stabilization

During the drilling phase the plate needs to be secured to the bone cortex to achieve the conical coupling; this can be done by conventional bone-clamps , with temporary conventional screws, with pins inserted through appropriate plate’s holes, or with pins inserted through the drill-guide and temporary secured with pin-stops.